In the assembly of mechanical products, the connection between parts mainly relies on fasteners. Among them, threaded fasteners are widely used, and the performance and connection effect of fasteners directly affect the performance, safety, and service life of products. The failure of fasteners is a common cause of quality problems in mechanical products. Therefore, analyzing the potential causes of failure modes of threaded fasteners is of great significance for improving product quality.
Common failure modes of threaded fasteners
The main failure modes of threaded fasteners encountered in our work can be divided into:
① Assembly twist and tear fracture;
② The thread is twisted and broken by shear force;
③ Fracture of stress concentration areas after use;
④ Fatigue fracture;
⑤ Delayed fracture;
⑥ Component torque alarm;
⑦ Thread slippage.
Analysis of the causes of two common failure modes
2.1 Assembly, twisting, pulling, and breaking
The characteristic of twist and pull fracture is obvious necking and elongation at the fracture site, and the common cause of twist and pull fracture is mainly due to the low friction coefficient of the connecting surface; Excessive torque applied during tightening or pre tightening, sleeve not aligned with thread axis during torque application, and excessive speed during torque application; The performance strength of the parts themselves is insufficient, and the perpendicularity between the fastening surface and the thread centerline exceeds the tolerance.
2.2 Thread breakage under shear force
The fracture site that is twisted by shear force generally has a spiral shape without obvious necking. The common reason for the thread to be twisted by shear force is that the thread is stuck during the tightening process, such as thread deformation, inconsistent tooth profiles of mutual connections, and welding slag lamps on the thread; The section where the bolt is screwed in is blocked, and if the nut is a blind hole, the effective thread depth is insufficient.
2.3 Fracture of stress concentration areas after use
The common manifestation of fracture in stress concentration areas after use is at the bolt head and the right angle between the head and the threaded rod. The common reason for fracture in stress concentration areas is that the rounded corner of the right angle between the head and the threaded rod is too small; There are defects in the plastic streamline at the head during cold heading of bolts. The perpendicularity between the connected surface and the bolt exceeds the tolerance.
2.4 Fatigue fracture
The main fracture during the use of bolted connections is fatigue fracture, which is commonly caused by insufficient preload force; Excessive attenuation of clamping force; Unqualified bolt size and performance; The mutual coordination between parts, assembly environment, and operating conditions cannot meet the design requirements.
2.5 Delayed fracture
The common cause of delayed fracture is hydrogen embrittlement, which is the trace amount of hydrogen that enters the interior of steel during production processes such as electroplating and welding, leading to material embrittlement or even cracking under residual or external stress. Common fasteners that are prone to hydrogen embrittlement include self tapping screws/elastic washers/bolts with electroplated surfaces of grade 8 or above.
2.6 Component torque alarm
The torque alarm of parts commonly occurs during the bolt assembly process controlled by angle method. The failure modes and reasons for the torque alarm of fasteners include: after assembly, the final torque of the parts is higher than the control upper limit or lower than the control lower limit. The reason is that the control range of the assembly torque of the parts is unreasonable, manifested as the set control range is too small, the control range is shifted upward or downward, as shown in Figure 1, where f above and f below are the friction coefficients.
Failure to pre tighten to the preset angle, torque reaching the upper limit alarm: The reason is that the friction coefficient of the parts themselves exceeds the upper limit, the friction coefficient of the parts fitting exceeds the upper limit, and there is interference between the parts, causing a sharp increase in assembly torque.
Normal assembly, torque lower limit alarm: The reason is that the friction coefficient of the part itself exceeds the lower limit or the friction coefficient of the part fitting exceeds the lower limit. When the part is screwed in, the fitting torque is greater than the initial torque (that is, the torque consumption is too high), which is commonly seen in the tightening of lock nuts.
2.7 Thread Sliding Teeth
Threaded connections often experience thread slippage, which is mainly caused by thread decarburization: common phenomena include feeling that torque cannot be applied during assembly, finding that all or part of the thread is ground flat after removing the bolt, and low surface hardness of the bolt thread or nut hole; Internal and external thread size fit: The mating connection has a small contact area, and there are two situations: one is that the number of threads that fit together is small, and the other is that the threads are not in contact with each other within the pitch diameter (i.e. poor precision fit, insufficient contact between bolt threads and nut threads).
At the same time, if the holes are not assembled correctly in the assembly method, strong tightening can also cause thread slippage; Low friction coefficient of threads: surface coating, surface roughness, unreasonable surface lubricant, foreign objects in bolt threads or threaded holes, damaged threads, and variations in pitch and angle between bolts and nuts can all cause thread slippage.
Analysis of 3 Failure Cases of Fasteners
3.1 Case Description
From March to April 2015, a certain final assembly provided feedback on a total of 5 pieces of fixing bolts for the rear shock absorbers of a certain vehicle model. When applying torque, the bolts shrank and broke, as shown in Figure 2. The required torque for this bolt is 110+/-15 N.m, the equipment setting value is 110 N.m, the thread specification is M12 × 1.75-6h, the performance level is 10.9, and the surface treatment is in accordance with GMW3359.
3.2 Composition of Tightening Torque
The tightening torque of the screw pair is the sum of the frictional resistance torque between the screw pairs and the frictional resistance distance between the nut ring surface and the supporting surface of the connected component. The calculation is as follows:
T1 is the friction torque between the helical pairs; T2 is the frictional resistance distance between the bolt ring surface and the supporting surface;
F0 is the preload force;
For steel bolts with M10~M64 coarse thread and ordinary thread, the thread pitch angle is 1 ° 42 ′ -3 ° 2 ′, and the equivalent friction angle of the helical pair is approximately arctan 1.155f (f is the friction coefficient, taken as 0.1~0.2 without lubrication);
D2 is the pitch diameter of the thread;
D0 is the diameter of the bolt hole, D0 is the annular outer diameter of the contact force between the nut (bolt) and the connected support surface;
Fc is the friction coefficient between the nut (bolt) and the supporting surface.
3.3 Analysis Process
Appearance inspection: There are residual black oil stains on the supporting surface of the broken bolt head, which are caused by the oil stains sticking to the installation surface of the connected parts.
Measurement of fractured bolt size: The major diameter of the fractured bolt was measured to be 10.4 mm (the measured thread major diameter of the unused product was 11.85 mm, which meets the standard), and the total length of the fractured bolt was 89.8 mm (the measured total length of the unused bolt was 85.5 mm, with a specified maximum of 85.9 mm). There were no abnormalities in other dimensions of the part.
The torque record of the fractured bolt is close to the median, and there is no deviation or exceedance; Drawing hardness requirement: 32-39 HRC: Tested hardness of fractured bolts: 36 HRC, 35 HRC, 36 HRC, 36 HRC, 37 HRC, qualified; No abnormalities were found in the metallographic structure of the fractured bolt, as shown in Figure 3; Two parts from each of the two batches in use were randomly inspected for tensile strength, and the results were qualified.
Three pieces from two batches in use were randomly tested for friction coefficients of 0.13, 0.13, and 0.12, which meet the drawing requirements of 0.10~0.16. Based on the detection results of broken bolts and randomly inspected bolts, it is preliminarily judged that the bolt parts meet the design requirements; Based on the analysis of the tightening torque of the spiral pair, it is preliminarily determined that the friction coefficient is reduced due to oil contamination on the connecting surface. Under the same assembly torque, the axial force borne by the bolt increases, leading to bolt fracture. After wiping the mounting surface of the shock absorber clean and assembling it, the problem did not occur again.